Tankless water heaters installed in Minneapolis

A tankless heater only makes hot water when a tap opens, so it never runs out and never keeps 50 gallons hot overnight. Getting there takes more than hanging a box on the wall: the gas line, the venting and the size all have to be right.

  • 24/7 calls answered
  • Minneapolis service office
  • Sized by GPM not by tank size
  • Wall-hung frees floor space

Quick answer

Installing a tankless water heater in a Minneapolis home means sizing it by gallons per minute at your coldest incoming water, running a larger gas line for a burner near 199,000 BTU, and venting it through PVC or stainless. Older homes often need the gas line upgraded, which is the biggest variable in the job.

Boilers & Water Heaters

Tankless is a different install, not a swap

Replacing a tank with another tank reuses the gas line, the vent and the floor space. Replacing it with a tankless unit changes all three. A large gas tankless heater needs several times the gas flow of a 40 gallon tank, dedicated venting, and a spot on a wall with water, gas and a drain nearby.

When those pieces line up, tankless is a good choice for households that run out of hot water or want the space back. When they do not, a power-vent or hybrid tank may be the better value, and we will price both.

Cost factors

What moves the price

Tankless installs vary more than tank swaps because the house decides how much has to change.

  • Gas line upgrade. The biggest variable; long runs from the meter cost the most.
  • Unit size and type. Condensing units cost more but vent through cheaper plastic pipe.
  • Venting route. A short side-wall run is simpler than a long run to an outside wall.
  • Condensate drain. Condensing units need a drain and a neutralizer.
  • Electrical. Tankless units need an outlet nearby for controls.
  • Water treatment. Very hard water may justify a softener or scale filter.
  • Removal of the old tank. Included, along with sealing the old chimney connection.

Gas line and venting upgrades

Upsized gas line to a tankless water heater

Most tank heaters run on a half-inch gas line. A whole-house tankless unit burning near 199,000 BTU often needs a three-quarter inch line, sized for its length from the meter and for every other gas appliance running at once. We measure the run, calculate the load and replace the line where needed. Venting is usually PVC or polypropylene for condensing units, or stainless for non-condensing ones, run to a side wall away from windows and snow. The old chimney connection is removed and sealed.

Sizing by flow rate

A tankless heater is sized by how many fixtures run at once and how much it has to raise the water temperature. In winter the incoming water is at its coldest, so the unit has to lift it further, and its flow rate drops. We count your showers, tubs and appliances, estimate the peak demand, and pick a unit that holds shower temperature with the dishwasher running in February. Very large homes sometimes get two units linked together rather than one oversized heater, which also keeps some hot water available if one unit needs service.

Descaling and annual service

Minerals in the water build up on the heat exchanger over time, lowering flow and triggering error codes. We install isolation valves on every tankless job so the unit can be flushed with a pump and descaling solution without cutting pipe. A yearly service includes that flush, cleaning the inlet screen, checking the condensate neutralizer on condensing units, and inspecting the vent and burner. It is the one maintenance item that decides whether a tankless heater lasts, and in hard water we may suggest doing it more often than once a year.

What we see on calls around Minneapolis

With about 43 percent of Minneapolis homes built before 1939, a lot of the houses we quote were piped for a furnace, a range and a small tank heater, not for a burner several times that size. That is why the gas line is the first thing we measure on a tankless job here. In many of these homes a three-quarter inch line from the meter makes the difference between steady hot water and a unit that throttles back when the furnace fires.

What is included

What a tankless install includes

  • Peak demand and gas load calculation
  • Gas line upgrade where needed
  • Wall-mounted unit on a solid backer
  • Isolation valve kit for descaling
  • PVC, polypropylene or stainless venting
  • Condensate drain and neutralizer
  • Old tank removed and chimney connection sealed
  • Flow and temperature test with fixtures running
  • Descaling interval and settings walkthrough
Tankless water heater with service valves and neutralizer

Step by step

How a tankless installation runs

  1. 1

    Measure demand and gas

    We count fixtures and measure the gas line from the meter.

  2. 2

    Pick the unit and route

    Size, venting path and mounting spot are decided.

  3. 3

    Upgrade the gas line

    The line is replaced or upsized where the load calls for it.

  4. 4

    Mount, pipe and vent

    Unit hung, water and gas connected, isolation valves and vent installed.

  5. 5

    Fire and test

    Flow and outlet temperature tested with several fixtures running.

Brands we service and install

On boilers and water heaters we see Weil-McLain, Navien, Bosch and Rheem most often.

Compare

Descaling yourself or having it done

HomeownerOur technician
Cleaning the inlet screenEasy with the water offChecked at every visit
Flushing with a pump kitPossible with isolation valvesDone with a burner and vent inspection
Clearing error codesSometimes a reset worksWe find the cause
Gas and venting workNot a DIY jobInstalled and tested

Questions we get on the phone

Tankless water heater installation questions from Minneapolis homeowners

More from this category

Related work we handle

Water Heater Installation

40 and 50 Gallon Gas Replacement and more.

Water Heater Installation in Minneapolis

Water Heater Repair

No Hot Water and more.

Details on pilot light keeps going out

Boiler Installation

Condensing Boiler Replacement and more.

Combi Boiler for Heat and Hot Water

Price a tankless heater for your house

Call and we will measure the gas line and demand, then price tankless alongside a tank option.

Reach us

Call, or find our Minneapolis service office

Phone
(612) 294-1420
Hours
Open 24 hours, seven days a week
Service office
7214 Cahill Rd, Minneapolis, MN 55439
Head office
15642 Kristin Ln, Carver, MN 55315
Coverage
Minneapolis and the southwest metro. See where we work

NHA VFD service office in Minneapolis, MN

Call (612) 294-1420